Õhk-vesi soojuspump 9 kw ja 11 kW split mudel eraldi asetseva tarbevee mahutiga

Split tüüpi soojuspump . Inverter kompressoriga mudelid.

Soodne lahendus eramu kütmiseks.

Juhib kütte ja tarbevee temperatuuri.

Küttevee reguleerimisgraafik välisõhu järgi koos toatemperatuuri korrektoriga.

Carel elektrooniline paisventiil.

Lisakütte juhtimine.

 

 


Model

 

AWH09

AWH11

Power Supply

V/Hz/Ph

220-240/50/1

220-240/50/1

Refrigerant

 

R410A

R410A






Max. Heating Capacity (2)

kW

10,1

11,5

C.O.P (2)

W/W

3.91

4

Heating Capacity Min./Max.(2)

kW

4.33/10,1

4.67/11,5

Heating Power Input Min./Max.(2)

kW

1,17/2,71

0,92/3,03

C.O.P Min./Max.(2)

W/W

3.70/4,21

3,82/5,05

Max. Heating Capacity(3)

kW

9,53

10,7

C.O.P (3)

W/W

2,92

2,95

Heating Capacity Min./Max.(3)

kW

4.19/9,53

4,14/10,70

Heating power input Min./Max.(3)

kW

1,43/3,19

1,22/3,62

C.O.P Min./Max.(3)

W/W

2,77/3.30

2,95/3.56

Max. Cooling Capacity(4)

kW

6,3

8,4

E.E.R (4)

W/W

2.01

2,71

Cooling Capacity Min./Max.(4)

kW

2.61/6,33

2,39/8,40

Cooling Power Input Min./Max.(4)

kW

1,43/3,48

0,99/3,4

E.E.R Min./Max.(4)

W/W

1,97/2,88

2,68/3,30

Max. Cooling Capacity(5)

kW

5,0

6,74

E.E.R(5)

W/W

1,73

2,17

Cooling Capacity Min./Max.(5)

kW

2.34/5,05

2.17/6,74

Cooling Power Input Min./Max.(5)

kW

1,30/3,20

092/3,13

E.E.R Min./Max.(5)

W/W

1,73/2,11

2.15/3.00

Circuit Max. Pressure

bar

38

38

Compressor

Type

Twin Rotary

Twin Rotary

Quantity/System

1

1

Fan

Quantity

 

1

1

Airflow

m3/h

3000

3200

Rated power

W

160

160

Air Side Heat Exchanger

Face area

m2

0.705

0,871

Row-Fins/Inch

2 Rows-14

2 Rows-14

Tube.Dia

Inch

3/8 O.D.

3/8 O.D.

Noise Level

Indoor/Outdoor

dB(A)

35/54

35/55

Water Side Heat Exchanger

Type

Plate Heat Exchanger

Plate Heat Exchanger

Water Pressure Drop

kPa

30

30

Piping Connection

Inch

G1"

G1"

Allowable Water Flow

Min. Water Flow

L/S

0.24

0.32

Rated Water Flow

0.395

0.53

Max. Water Flow

0.48

0.63

 

 

 

 

 


        (2) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;

        (3) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;

        (4) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;

        (5) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃;

        (6) The specifications are subject to change without prior notice. For actual specifications of unit,

               please refer to the stickers on the unit.


 

 

 

Veemahuti: RST, 200l, tarbevee siug 40 m, 2 kW tenn

Lämminvesivaraaja: RST, 200l, kierukka 40 m, 2 kW vastus

Tarbevesi split soojuspumbaga.

Manual